-
AboutWuhan Zhongke Xinyi Electric Power Technology Co., Ltd. (brand: ZECERS/Zhongke Xinyi) is a high-tech enterprise focusing on the design, development, manufacturing and technical services of high-voltage test equipment and secondary test equipment for power systems.
-
NewsWuhan Zhongke Xinyi Electric Power Technology Co., Ltd. (brand: ZECERS/Zhongke Xinyi) is a high-tech enterprise focusing on the design, development, manufacturing and technical services of high-voltage test equipment and secondary test equipment for power systems.
-
Service SupportWuhan Zhongke Xinyi Electric Power Technology Co., Ltd. (brand: ZECERS/Zhongke Xinyi) is a high-tech enterprise focusing on the design, development, manufacturing and technical services of high-voltage test equipment and secondary test equipment for power systems.
-
SolutionWuhan Zhongke Xinyi Electric Power Technology Co., Ltd. (brand: ZECERS/Zhongke Xinyi) is a high-tech enterprise focusing on the design, development, manufacturing and technical services of high-voltage test equipment and secondary test equipment for power systems.
-
ContactWuhan Zhongke Xinyi Electric Power Technology Co., Ltd. (brand: ZECERS/Zhongke Xinyi) is a high-tech enterprise focusing on the design, development, manufacturing and technical services of high-voltage test equipment and secondary test equipment for power systems.
current
ZEC-802C three-phase relay protection tester
The flexible combination type of voltage and current output has a standard 4-phase voltage and 3-phase current output, which can easily carry out various combination outputs for various types of protection tests. Each phase voltage can output 120V, current three can output 120A, the fourth phase voltage Ux is a multi-function voltage item, which can be set to 4 kinds of 3U0 or check the same period voltage, or any certain voltage value.
ZBLQ-203B zinc oxide arrester charged tester
ZBLQ-203B zinc oxide arrester charged tester is a special instrument for testing the electrical performance of zinc oxide arrester, the instrument is suitable for various voltage levels of zinc oxide arrester charged or power failure detection, so as to timely find the equipment internal insulation moisture and valve aging and other dangerous defects.
ZEHL-100A loop resistance tester
At present, the conventional QJ44 double-arm DC bridge is generally used in the power system for measuring contact resistance, and the test current of this kind of bridge is only mA level, so it is difficult to find the defect of reducing the cross-sectional area of the loop conductor. When measuring the contact resistance of the conductive loop of high-voltage switch, due to the influence of oil film and oxide layer between contacts, the measured value is several times larger and cannot truly reflect the contact resistance value. To this end, the Ministry of Electric Power's standard SD301-88 "AC 500KV Power Equipment Handover and Preventive Test Procedures" and the new version of "Power Equipment Preventive Test Procedures" stipulate that the measured current of contact resistance of circuit breakers and isolating switches shall not be less than DC 100A to ensure accurate test results.
Key words:
Latest Products
Latest News
WeChat Public Number
Business consulting
Service hotline
Office telephone:027-82818935
Company fax: 027-87747006
Company Email:zecers@163.com
Website:www.zecers.com
Company address: No.62 Guanggu Avenue, Donghu High-tech Development Zone, Wuhan City
SAF Coolest v1.3.1.1 设置面板 VTFSX-ANZU-QAAZE-SSV
无数据提示
Sorry, the current column is being updated, please look forward to it!
You can view other columns or returnHome Page