ZFZK-502B generator rotor AC impedance tester


Generator rotor winding inter-turn short circuit is a common fault in power system. When this kind of fault occurs, the rotor current increases and the winding temperature increases, which limits the output of the generator and affects the normal operation of the generator in severe cases. Inter-turn short circuit is usually determined by measuring the AC impedance and power loss of the generator rotor winding. The traditional measurement method is to use multiple test instruments and meters to measure after on-site assembly. This method, which requires a lot of test instruments and meters to form a measurement system, has the disadvantages of heavy test equipment, time-consuming and laborious, cumbersome data sorting and low measurement accuracy.
Picture Name

Key words:

Generator testing instrument

measurement



Message
  • Product Description
  • Technical parameters
  • Product selection
  • Manual Resources
  • Test wiring
  • ACCESSORIES LIST
    • Commodity name: ZFZK-502B generator rotor AC impedance tester

    Generator rotor winding inter-turn short circuit is a common fault in power system. When this kind of fault occurs, the rotor current increases and the winding temperature increases, which limits the output of the generator and affects the normal operation of the generator in severe cases. Inter-turn short circuit is usually determined by measuring the AC impedance and power loss of the generator rotor winding. The traditional measurement method is to use multiple test instruments and meters to measure after on-site assembly. This method, which requires a lot of test instruments and meters to form a measurement system, has the disadvantages of heavy test equipment, time-consuming and laborious, cumbersome data sorting and low measurement accuracy.

    1. Overview:

    Generator rotor winding inter-turn short circuit is a common fault in power system. When this kind of fault occurs, the rotor current increases and the winding temperature increases, which limits the output of the generator and affects the normal operation of the generator in severe cases. Inter-turn short circuit is usually determined by measuring the AC impedance and power loss of the generator rotor winding. The traditional measurement method is to use multiple test instruments and meters to measure after on-site assembly. This method, which requires a lot of test instruments and meters to form a measurement system, has the disadvantages of heavy test equipment, time-consuming and laborious, cumbersome data sorting and low measurement accuracy.

    With the continuous development of digital signal processing technology, new microprocessors and algorithms are constantly emerging, according to which we developed a generator rotor AC impedance tester based on digital signal processor. The instrument takes the digital signal processing system as the hardware platform, gives full play to the computing power of the digital signal processor, makes the calculation speed and calculation accuracy of the instrument greatly improved, and provides a guarantee for the normal operation of the power system.

      

    2. features

    • Automatic (manual) acquisition, measurement, display, storage, printing of all measurement parameters and AC impedance characteristic curve;

    • Real-time display of measurement data and AC impedance characteristic curve, easy to store and print;

    • Using 320 × 240 large-screen LCD display, Chinese menu prompts, easy to operate;

    Built-in large-capacity non-volatile memory: can store 200 sets of measurement data and curves;

    Built-in high-precision real-time clock function: date and time calibration;

    • With high-speed micro thermal printer: can print measurement and historical data;

    • No-load, short-circuit test of single-phase transformer and volt-ampere characteristic test of voltage (current) transformer and arc suppression coil;

    • It has perfect over-voltage and over-current protection function, in which the over-voltage and over-current protection value is automatically adjusted according to the setting of test parameters, which is simple and can ensure the safety of the tested equipment.

  • 2.Technical parameters

    Measurement range impedance: 0 ~ 999.9Ω

    Voltage: 0~600V

    Current: 0 ~ 120A

    Power: 0 ~ 72kW

    Speed: 0~3600rpm

    Frequency: 45~65Hz

    Accuracy voltage, current, speed, frequency: 0.2

    Impedance: 0.5 level

    Power: 0.5 level (cosφ>0.5), 1.0 level (0.5 ≥cosφ ≥ 0.2)

    Dimensions 345mm × 295mm × 175mm

    Instrument weight 5kg

     

  • Attachment Download:ZFZK-502B generator rotor AC impedance tester user manual.

     

Quality first, service first

Tree industry standards, do a hundred years of enterprises.

Wuhan Zhongke Xinyi Electric Power Technology Co., Ltd.

Brand: ZECERS/Zhongke Xinyi

Company establishment

Registered capital

Production plant

Customer Service


If you are interested in our products and want to know more details, please leave a message here and we will reply you as soon as possible.

Security verification
Submission