ZEC4106 grounding resistance tester


The ZEC4106 grounding resistance tester has a unique line resistance verification function, which is more accurate in measuring low-value grounding resistance on site and can avoid errors caused by changes in line resistance due to long-term use of the test line. Can avoid errors caused by incomplete insertion of the test line into the instrument interface or poor contact; Can avoid errors caused by users replacing or lengthening the test line, etc.
Picture Name

Key words:

resistance



Message
  • Product Description
  • Technical parameters
  • Product selection
  • Manual Resources
  • Test wiring
  • ACCESSORIES LIST
    • Commodity name: ZEC4106 grounding resistance tester

    The ZEC4106 grounding resistance tester has a unique line resistance verification function, which is more accurate in measuring low-value grounding resistance on site and can avoid errors caused by changes in line resistance due to long-term use of the test line. Can avoid errors caused by incomplete insertion of the test line into the instrument interface or poor contact; Can avoid errors caused by users replacing or lengthening the test line, etc.

    1. main features:

    The ZEC4106 grounding resistance tester is specially designed for field measurement of grounding resistance. It adopts digital and micro-processing technology, 3-wire or 2-wire method to measure grounding resistance. It has unique line resistance verification function, anti-interference ability and environmental adaptability to ensure high precision, high stability and reliability of long-term measurement. The instrument shell adopts a waterproof protection box, which is anti-collision, anti-drop, waterproof (protection grade IP65), strong, safe and durable. The instrument is also equipped with a large-capacity rechargeable lithium battery pack, which is especially suitable for outdoor construction sites. It is widely used in electric power, telecommunications, meteorology, construction, lightning protection and industrial electrical equipment grounding resistance measurement.

    The ZEC4106 grounding resistance tester has a unique line resistance verification function, which is more accurate in measuring low-value grounding resistance on site and can avoid errors caused by changes in line resistance due to long-term use of the test line. Can avoid errors caused by incomplete insertion of the test line into the instrument interface or poor contact; Can avoid errors caused by users replacing or lengthening the test line, etc.

    The ZEC4106 grounding resistance tester is composed of the host, monitoring software, test line, communication line, etc. Host large LCD display, white screen backlight, stick chart instructions, at a glance. At the same time, it can store 400 groups of data, realize historical query and online real-time monitoring function through monitoring software, dynamic display, with maximum, minimum and average value indication, alarm value setting and alarm indication function, and historical data reading, consulting, saving, reporting, printing and other functions.

  • 1.Technical Specifications:

    1. Baseline and operating conditions

    Amount of impact Baseline conditions Working conditions Remarks
    Ambient temperature 23 ℃ ± 1 ℃ -10 ℃ ~ 40 ℃ ---- 
    Ambient humidity 40%~60% <80% ----
    Instrument working voltage DC 7.8V±0.1V DC 7.8V±0.6V ----
    Auxiliary grounding resistance <100Ω <30kΩ rC、rP
    Interference voltage None <20V ----
    interference current None <2A ----
    Electrode spacing when measuring R a>5d a>5d ----

     

    2. General specifications

    Function Resistance to ground measurement, voltage to ground measurement, low value resistance measurement
    Power DC 7.4V 2600mAh rechargeable lithium battery, the battery is full of about DC 8.4V
    Backlight Controllable white screen backlight, suitable for use in dim places
    Measurement mode Precision three-wire measurement, simple two-wire measurement
    Measurement method Grounding resistance: rated current pole changing method, measuring current 20mA Max;
    Voltage to ground: average value rectified
    Test frequency 128Hz/111Hz/105Hz/94Hz(AFC)
    Short-circuit test current AC 20mA max
    Line resistance calibration Avoid errors caused by the test line not being fully inserted into the instrument interface or poor contact or the user replacing the extended test line, so that the ground resistance measurement is more accurate.
    Display Mode 4-digit large LCD display, white screen backlight
    Measurement indication LED flashing indication during measurement, LCD countdown display
    LCD Size 128mm × 75mm; Display field: 124mm × 67mm
    Instrument size Height and width: 280mm × 260mm × 160mm
    Data Mode Average, maximum, minimum
    Test line 3: red 15m, yellow 10m, green 5m each 1
    Simple test line 2: red 1.6m, black 1.6m each 1
    Auxiliary grounding rod 2: φ9mm × 230mm measurement time voltage to ground: about 3 times/second; Grounding resistance: about 15 seconds/time
    Number of measurements More than 5000 times
    (Measure 10Ω at 20Ω gear, measure once, stop for 30 seconds and then measure again)
    Line voltage Measurement of voltage to ground: AC 600V measurement below
    Communication Interface With USB interface, software monitoring, storage data can be uploaded to the computer, save print
    Communication line One USB communication line, 1.5m long data storage 400 group, flashing "FULL" symbol indicates that the storage is full
    Data retention Data retention function: "HOLD" symbol display
    Data access Data access function: "READ" symbol display
    overflow display Overrange overflow function: "OL" symbol display
    Alarm function When the measured value exceeds the alarm set value, "beep-beep-beep-" alarm prompt
    Automatic shutdown 10 minutes after the boot, automatic shutdown
    Battery voltage When the battery voltage drops to DC 7.2V ± 0.1V, the battery voltage low symbol""display, remind the battery must be charged
    Working current
     
    Backlight: 25mA Max
    Standby: 25mA Max (backlight off)
    Measurement: 200mA Max (backlight off)
    Quality Instrument: about 4730g (including battery)
    Test line: about 847g (including simple test line)
    Auxiliary grounding rod: about 468g(2 pieces)
    Total mass: about 5kg (including accessories)
    Working temperature and humidity -10 ℃ ~ 40 ℃; below 80% rh
    Storage temperature and humidity -20 ℃ ~ 60 ℃; below 70% rh
    Protection level IP65 (when closed)
    Overload protection Measurement of grounding resistance: AC 280V/3 seconds between E-P and E-C ports
    Insulation resistance Above 10MΩ (500V between circuit and housing)
    Withstand voltage AC 3700V/rms (between circuit and case)
    electromagnetic characteristics IEC61010-4-3, radio frequency electromagnetic field ≤ 1 V/m
    Suitable for safety regulations IEC61010-1, IEC 1010-2-31, IEC61557-1, Pollution Class 2, CAT III
    300V

     

  • Product Name Product Model Function Remarks
    Grounding resistance tester ZEC4106 Ground resistance test
    Ground voltage test
     

     

  • Attachment Download:ZEC4106 ground resistance tester user manual. doc.

     

  • PackingList

    Instrument 1
    Toolkit 1 Piece
    Auxiliary grounding rod 2
    USB communication line 1 Article
    Test line 3 (red 15m; Yellow 10m; One green 5m each)
    Simple test line 2 (red 1.6m; One green 1.6m each)
    Dedicated charger 1
    User Manual/Warranty Card/Certificate 1 part


     

Quality first, service first

Tree industry standards, do a hundred years of enterprises.

Wuhan Zhongke Xinyi Electric Power Technology Co., Ltd.

Brand: ZECERS/Zhongke Xinyi

Company establishment

Registered capital

Production plant

Customer Service


If you are interested in our products and want to know more details, please leave a message here and we will reply you as soon as possible.

Security verification
Submission