ZEHL-100A loop resistance tester


At present, the conventional QJ44 double-arm DC bridge is generally used in the power system for measuring contact resistance, and the test current of this kind of bridge is only mA level, so it is difficult to find the defect of reducing the cross-sectional area of the loop conductor. When measuring the contact resistance of the conductive loop of high-voltage switch, due to the influence of oil film and oxide layer between contacts, the measured value is several times larger and cannot truly reflect the contact resistance value. To this end, the Ministry of Electric Power's standard SD301-88 "AC 500KV Power Equipment Handover and Preventive Test Procedures" and the new version of "Power Equipment Preventive Test Procedures" stipulate that the measured current of contact resistance of circuit breakers and isolating switches shall not be less than DC 100A to ensure accurate test results.
Picture Name

Key words:

resistance

power

current



Download Product Brochure:

Message
  • Product Description
  • Technical parameters
  • Product selection
  • Manual Resources
  • Test wiring
  • ACCESSORIES LIST
    • Commodity name: ZEHL-100A loop resistance tester

    At present, the conventional QJ44 double-arm DC bridge is generally used in the power system for measuring contact resistance, and the test current of this kind of bridge is only mA level, so it is difficult to find the defect of reducing the cross-sectional area of the loop conductor. When measuring the contact resistance of the conductive loop of high-voltage switch, due to the influence of oil film and oxide layer between contacts, the measured value is several times larger and cannot truly reflect the contact resistance value. To this end, the Ministry of Electric Power's standard SD301-88 "AC 500KV Power Equipment Handover and Preventive Test Procedures" and the new version of "Power Equipment Preventive Test Procedures" stipulate that the measured current of contact resistance of circuit breakers and isolating switches shall not be less than DC 100A to ensure accurate test results.

    1. Product Overview

    At present, the conventional QJ44 double-arm DC bridge is generally used in the power system for measuring contact resistance, and the test current of this kind of bridge is only mA level, so it is difficult to find the defect of reducing the cross-sectional area of the loop conductor. When measuring the contact resistance of the conductive loop of high-voltage switch, due to the influence of oil film and oxide layer between contacts, the measured value is several times larger and cannot truly reflect the contact resistance value. To this end, the Ministry of Electric Power's standard SD301-88 "AC 500KV Power Equipment Handover and Preventive Test Procedures" and the new version of "Power Equipment Preventive Test Procedures" stipulate that the measured current of contact resistance of circuit breakers and isolating switches shall not be less than DC 100A to ensure accurate test results.

    This product is based on the latest the People's Republic of China power implementation standard DL/T845.4-2019, using high-frequency switching power supply technology and digital circuit technology combined design. It is suitable for the measurement of circuit resistance of switch control equipment. The test current adopts the DC 100A recommended by the national standard. The loop resistance can be measured directly at a current of 100A and displayed digitally. The instrument is accurate in measurement, stable in performance, and meets the requirements of on-site high-voltage switch maintenance and high-voltage switch factory circuit resistance testing in power and power supply departments.

     

    II Use

    This product is suitable for high-precision measurement of high-voltage switch contact resistance (loop resistance), and is also suitable for other occasions that require high current and micro-resistance measurement.

      

    3. performance characteristics

    (1) large current: using the latest power supply technology, can continuously output large current for a long time, overcome the shortcomings of the pulse power supply instantaneous current, can effectively break down the switch contact oxide film, get good test results.

    (2) Strong anti-interference ability: Under severe interference conditions, the last bit of data on the LCD screen can be stabilized within ± 1 word range, with stable readings and good repeatability.

    (3) Long service life: All high-precision resistors are used to effectively eliminate the influence of ambient temperature on the measurement results. At the same time, the use of military connectors enhances the anti-vibration performance.

    (4) easy to carry: small size, light weight.

  • 2.Technical parameters:

    1. Measurement range: 1 ~ 1999μΩ

    2. Resolution: 1μΩ

    3. Test current: DC 100A

    4. Measurement accuracy: 0.5%± 1d

    5. Display mode: current: three-and-a-half digital tube; resistance: three-and-a-half digital tube

    6. Working power supply: AC220V ± 10PHz

    7. Working environment: temperature -10 ℃ ~ 40 ℃ humidity: ≤ 80% RH

    8. Volume: 390 × 300 × 150 mm3

    9. Weight: 6Kg (excluding accessories)

  • Attachment Download:ZEHL-100A loop resistance testerUser Manual. doc.

     

  • Packing List

    1. Host 1

    2. One set of special test lines (two high current lines 6m, two high current test clips and two voltage test lines 6m)

    3.1 grounding wire

    4, 8A insurance tube 3

    5.1 accessory package

    6.1 AC 220V power cord

    7. Instruction 1

    8. One copy of factory inspection report

    9. One certificate

Quality first, service first

Tree industry standards, do a hundred years of enterprises.

Wuhan Zhongke Xinyi Electric Power Technology Co., Ltd.

Brand: ZECERS/Zhongke Xinyi

Company establishment

Registered capital

Production plant

Customer Service


If you are interested in our products and want to know more details, please leave a message here and we will reply you as soon as possible.

Security verification
Submission