  • 12(1714975222627).png

10KVA and above, can be customized


Oil immersed test transformer (hereinafter referred to as the test transformer), also known as booster, it is the power station, power supply and distribution system and scientific research units and other users of the basic test equipment. It is used to test the insulation strength of various electrical products, electrical equipment, insulation materials, etc. under the specified voltage, assess the insulation level of the product, find the insulation defects of the tested product, and measure the ability to withstand overvoltage.
Picture Name

Key words:

test

power

insulation



Message
  • Product Description
  • Technical parameters
  • Product selection
  • Manual Resources
  • Test wiring
  • ACCESSORIES LIST
    • Commodity name: 10KVA and above, can be customized

    Oil immersed test transformer (hereinafter referred to as the test transformer), also known as booster, it is the power station, power supply and distribution system and scientific research units and other users of the basic test equipment. It is used to test the insulation strength of various electrical products, electrical equipment, insulation materials, etc. under the specified voltage, assess the insulation level of the product, find the insulation defects of the tested product, and measure the ability to withstand overvoltage.

    1. Overview:

    Oil immersed test transformer (hereinafter referred to as the test transformer), also known as booster, it is the power station, power supply and distribution system and scientific research units and other users of the basic test equipment. It is used to test the insulation strength of various electrical products, electrical equipment, insulation materials, etc. under the specified voltage, assess the insulation level of the product, find the insulation defects of the tested product, and measure the ability to withstand overvoltage.

      

    2. structure

    AC type test transformer, AC and DC dual-purpose light high-voltage test transformer is made of high-quality cold-rolled silicon steel sheet. The coil is a concentric pagoda-shaped multi-layer cylinder, with low-voltage coils inside and high-voltage coils outside; the shell is portable, with the advantages of small size, light weight, beautiful appearance, and convenient movement.

      

    3. working principle

    The power frequency 220V (380V above 10KVA) power supply is connected to the control box (set) (for supporting equipment of the test transformer, please refer to the instruction manual of the control box (set) for details), and the voltage of 0-220V/380V adjusted by the self-coupling voltage regulator is input to the primary winding of the test transformer. According to the principle of electromagnetic induction, the voltage amplitude of the same multiple-power frequency high voltage-is obtained in the secondary (high voltage) winding according to its ratio to the number of turns of the primary winding. This power frequency high voltage can be obtained by high-voltage silicon stack rectification and capacitor filtering, and the amplitude is twice the effective value of the power frequency high voltage.

    This series of products are divided into three categories: AC type, AC and DC dual-purpose type, at the same time can be connected with a 200V tap into a series test transformer.

  • ACCESSORIES LIST

    1. Technical parameters of AC test transformer

    Capacity (KVA)

    High voltage output voltage (KV)

    High Voltage Output Current (mA)

    Low voltage input

    transformation ratio

    Temperature rise ℃ 30 minutes

    V

    A

    1.5

    50

    30

    200

    7.5

    500

    10

    3

    50

    60

    200

    15

    500

    10

    5

    50

    100

    200

    25

    500

    10

    10

    50

    200

    220/380

    50/26

    500

    10

    20

    50

    400

    380

    53

    500

    10

    30

    50

    600

    380

    79

    500

    10

    40

    50

    800

    380

    105

    500

    10

    50

    50

    1000

    380

    132

    500

    10

    5

    100

    50

    200

    25

    1000

    10

    10

    100

    100

    200/380

    50/26

    1000

    10

    20

    100

    200

    380

    53

    1000

    10

    30

    100

    300

    380

    79

    1000

    10

    40

    10

    400

    380

    105

    1000

    10

    50

    100

    500

    380

    132

    1000

    10

    100

    100

    100

    500

    263

    1000

    10

    150

    100

    1500

    500

    300

    1000

    10

    200

    100

    2000

    500

    400

    1000

    10

    250

    100

    2500

    380

    500

    1000

    10

    20

    150

    133

    380

    53

    1500

    10

    30

    150

    200

    380

    79

    1500

    10

    50

    150

    333

    380

    132

    1500

    10

    100

    150

    666

    500

    263

    1500

    10

    150

    150

    1000

    500

    300

    1500

    10

    200

    150

    1333

    500

    400

    1500

    10

    250

    150

    1666

    380

    500

    1500

    10

    30

    200

    150

    380

    79

    2000

    10

    50

    200

    250

    380

    132

    2000

    10

    100

    200

    500

    380

    263

    2000

    10

    150

    200

    750

    500

    300

    2000

    10

    200

    200

    1000

    500

    400

    2000

    10

    250

    200

    1250

    500

    500

    2500

    10

    30

    250

    120

    380

    79

    2500

    10

    50

    250

    200

    380

    132

    2500

    10

    100

    250

    400

    380

    263

    2500

    10

    150

    250

    600

    500

    300

    2500

    10

    200

    250

    800

    500

    400

    2500

    10

    250

    250

    1000

    500

    500

    2500

    10

    Note: The input voltage of 100KVA and above can be increased to 3000V or proposed by the user.

     

    2. Technical parameters of AC/DC test transformer:

    Capacity (KVA)

    High voltage output (KV)

    High Voltage Current (mA)

    Low voltage input

    transformation ratio

    Temperature rise ℃ 30 minutes

    AC

    DC

    AC

    DC

    Voltage V

    Current A

    1.5

    50

    70

    30

    15

    200

    7.5

    500

    10

    3

    50

    70

    60

    15

    200

    15

    500

    10

    5

    50

    70

    100

    15

    200/380

    25

    500

    10

    10

    50

    70

    200

    100

    380

    50/26

    500

    10

    20

    50

    70

    400

    100

    380

    53

    500

    10

    30

    50

    70

    600

    100

    380

    79

    500

    10

    40

    50

    70

    800

    100

    380

    105

    500

    10

    50

    50

    70

    1000

    100

    380

    132

    500

    10

    5

    100

    140

    100

    50

    200/380

    25

    1000

    10

    10

    100

    140

    200

    100

    380

    50/26

    1000

    10

    20

    100

    140

    300

    100

    380

    53

    1000

    10

    30

    100

    140

    400

    100

    380

    79

    1000

    10

    40

    100

    140

    600

    100

    380

    105

    1000

    10

    50

    100

    140

    1000

    100

    380

    132

    1000

    10

  • 2

  • Attachment Download:ZYDJ-10kVA-100kV test transformer user manual. doc.

     

  • Test wiring

    1. AC (power frequency) withstand voltage test wiring diagram

    1

    Note: When doing AC withstand voltage test, either AC test transformer or AC/DC test transformer can be used. However, when using AC and DC to do AC withstand voltage test, it is not necessary to pull out the short-circuit rod on the high-voltage column.

     

    2. DC leakage and DC withstand voltage test wiring diagram

    1

    Description:

    2.1 When doing DC leakage and DC withstand voltage test, only AC and DC test transformer can be used, and the short-circuit rod on the high-voltage column must be pulled out during use.

    2.2 do cable withstand voltage does not need another and capacitor, available voltage divider, voltage divider more intuitive, accurate readout of high voltage voltage value.

    When 2.3 do DC leakage, the micro-ammeter can directly read out the DC leakage value.

    After 2.4 the DC leakage, the DC withstand voltage test can be carried out directly without removing the wire.

    2.5 The capacitor shall be added during the lightning arrester test.

    3. Wiring of series excitation combination test transformer

    3.1 AC series high voltage test transformer, several test transformers can be formed by appropriate combination of extremely high voltage test transformers. The principle is to wind the excitation winding in the high-voltage winding of the test transformer, and the winding has the same parameters as the primary coil of the next test transformer.

    Schematic diagram of 3.2 two test transformer series excitation wiring

    1

    3. Schematic Diagram of Series Connection of Three Test Transformers

    1

    Description:

    The control box (set) supplies the power supply for the primary winding of the first-stage test transformer. The tail end of the first-stage high-voltage winding is grounded to the shell, and the head end is connected to the high-voltage tail end of the second-stage test transformer and the shell. The excitation power supply of the second stage low voltage winding is supplied by the first stage series tap. Similarly, the third stage can be superimposed, then the output voltage of the third stage test transformer is the sum of the three test transformer voltages, I .e. u total = u1 + u2 + u3, and the capacity of the three test transformer meets the relation s total = s3 × 3.

    3.4 can form a DC series excitation test transformer, only the silicon stack with 2u is added to the test transformer with the highest voltage after AC series excitation.

    Note: 

    1. The test transformer shall be used together with the control box (Taiwan). For how to use the control box (Taiwan), please refer to the Operation Manual of the Control Box (Taiwan).

    2. DC test application of shielded wire, in order to eliminate stray leakage. After the test, the stored charge shall be discharged with a discharge rod.

    3. The grounding wire at the end of the high-voltage filter capacitor and the protective grounding wire (control box shell) should be reliably grounded.

    4. The high-voltage test site should comply with the high-voltage test operating procedures, pay attention to equipment and personal safety.

  • ACCESSORIES LIST

    1.1 high voltage output line (to be indicated when ordering, generally not equipped);

    2.1 instruction manual;

    3. One test report;

    4. Product certificate/warranty card 1 copy.
     

Quality first, service first

Tree industry standards, do a hundred years of enterprises.

Wuhan Zhongke Xinyi Electric Power Technology Co., Ltd.

Brand: ZECERS/Zhongke Xinyi

Company establishment

Registered capital

Production plant

Customer Service


If you are interested in our products and want to know more details, please leave a message here and we will reply you as soon as possible.

Security verification
Submission